NeoFix™ Fixed Hybrid

Parallax Image
Parallax Image
Parallax Image

Fixed Forever

Patients requesting a fixed, non-removable full-arch solution

Fixed Forever

Patients requesting a fixed, non-removable full-arch solution

Fixed Forever

Patients requesting a fixed, non-removable full-arch solution

High Stability

Full-arch implant restorations requiring high stability

High Stability

Full-arch implant restorations requiring high stability

High Stability

Full-arch implant restorations requiring high stability

Controlled Occlusion

Cases requiring controlled occlusion and long-term durability

Controlled Occlusion

Cases requiring controlled occlusion and long-term durability

Controlled Occlusion

Cases requiring controlled occlusion and long-term durability

Bar Based

Bar-based full-arch treatment plans

Bar Based

Bar-based full-arch treatment plans

Bar Based

Bar-based full-arch treatment plans

Fixed, screw-retained full-arch hybrid prosthesis seated over a verified CAD/CAM bar with metal mesh reinforcement controlled occlusion, long-term stability.

Fixed, screw-retained full-arch hybrid prosthesis seated over a verified CAD/CAM bar with metal mesh reinforcement controlled occlusion, long-term stability.

Fixed, screw-retained full-arch hybrid prosthesis seated over a verified CAD/CAM bar with metal mesh reinforcement controlled occlusion, long-term stability.

Materials

Materials

Choice of Materials

Flexible material choices to ensure optimal performance and natural-looking outcomes.

NeoFix™ CAD/CAM Titanium bar

NeoFix™ CAD/CAM Titanium bar

Screw-retained final prosthesis

Screw-retained final prosthesis

Gingival characterization per Rx.

Gingival characterization per Rx.

WORKFLOW.

WORKFLOW.

Case Workflow

Step by Step

01

Verification & Records

Lab Provides:

CAD/CAM-milled 3D Verification Jig

Backup custom tray designed to fit over the verification jig

Bite block with two cylinders for VDO and bite registration

Doctor Performs:

Seat verification jig and confirm passive fit

Capture bite record using the bite block

Jig misfit requires suction and new pickup impression with custom tray.

Purpose:

Verify implant position, bar accuracy, and bite before prosthesis fabrication.

Verification & Records

Lab Provides:

CAD/CAM-milled 3D Verification Jig

Backup custom tray designed to fit over the verification jig

Bite block with two cylinders for VDO and bite registration

Doctor Performs:

Seat verification jig and confirm passive fit

Capture bite record using the bite block

Jig misfit requires suction and new pickup impression with custom tray.

Purpose:

Verify implant position, bar accuracy, and bite before prosthesis fabrication.

02

Hybrid Try-In & Approval

Lab Provides:

NeoFix™ CAD/CAM bar

NeoClip™ CAD/CAM metal mesh reinforcement

Teeth set-up over mesh and CAD/CAM bar

Doctor Confirms:

Esthetics (midline, smile line, tooth display)

Phonetics, VDO, Screw access positions

Passive seating over the bar

Purpose:

Lock esthetics, function, and prosthesis design prior to final processing.

Hybrid Try-In & Approval

Lab Provides:

NeoFix™ CAD/CAM bar

NeoClip™ CAD/CAM metal mesh reinforcement

Teeth set-up over mesh and CAD/CAM bar

Doctor Confirms:

Esthetics (midline, smile line, tooth display)

Phonetics, VDO, Screw access positions

Passive seating over the bar

Purpose:

Lock esthetics, function, and prosthesis design prior to final processing.

03

Final Fabrication & Delivery

Lab Delivers:

Final NeoFix™ fixed screw-retained hybrid prosthesis

Gingival characterization (per Rx)

Finished, polished, and QC-verified prosthesis

Doctor Performs:

Final seating and torque protocol

Occlusal refinement if required

Deliver maintenance and recall instructions

Purpose:

Deliver a stable, fixed full-arch restoration with verified fit and controlled occlusion.

Final Fabrication & Delivery

Lab Delivers:

Final NeoFix™ fixed screw-retained hybrid prosthesis

Gingival characterization (per Rx)

Finished, polished, and QC-verified prosthesis

Doctor Performs:

Final seating and torque protocol

Occlusal refinement if required

Deliver maintenance and recall instructions

Purpose:

Deliver a stable, fixed full-arch restoration with verified fit and controlled occlusion.

Case Workflow

Step by Step

01

Verification & Records

Lab Provides:

CAD/CAM-milled 3D Verification Jig

Backup custom tray designed to fit over the verification jig

Bite block with two cylinders for VDO and bite registration

Doctor Performs:

Seat verification jig and confirm passive fit

Capture bite record using the bite block

Jig misfit requires suction and new pickup impression with custom tray.

Purpose:

Verify implant position, bar accuracy, and bite before prosthesis fabrication.

Verification & Records

Lab Provides:

CAD/CAM-milled 3D Verification Jig

Backup custom tray designed to fit over the verification jig

Bite block with two cylinders for VDO and bite registration

Doctor Performs:

Seat verification jig and confirm passive fit

Capture bite record using the bite block

Jig misfit requires suction and new pickup impression with custom tray.

Purpose:

Verify implant position, bar accuracy, and bite before prosthesis fabrication.

02

Clip Prosthesis Try-In & Approval

Lab Provides:

NeoClip™ CAD/CAM bar

NeoClip™ CAD/CAM metal mesh reinforcement

Teeth set-up with clip housing positions established

Doctor Confirms:

Esthetics (smile line, tooth display)

Phonetics, VDO, Path of insertion and removal

Bar seating and teeth try-in over the bar

Purpose:

Approve prosthesis design and retention strategy prior to final processing.

Clip Prosthesis Try-In & Approval

Lab Provides:

NeoClip™ CAD/CAM bar

NeoClip™ CAD/CAM metal mesh reinforcement

Teeth set-up with clip housing positions established

Doctor Confirms:

Esthetics (smile line, tooth display)

Phonetics, VDO, Path of insertion and removal

Bar seating and teeth try-in over the bar

Purpose:

Approve prosthesis design and retention strategy prior to final processing.

Build Your Case

Start your case with precision workflows, flexible materials, and expert lab support at every step.

Number of implants

FAQ.

FAQ.

NeoFix™ Hybrid Support FAQs

Find answers about product specifications, workflows, and what to expect for each case.

NeoFix™ vs NeoClip™ — when do I prescribe which?

NeoFix™ is fixed/screw-retained — the doctor removes it for service, the patient does not. NeoClip™ is removable — the patient takes it out for hygiene. Choose by patient preference, hygiene capability, and whether retrievability matters.

Can a NeoFix™ case use immediate-load on surgery day?

Yes — pair NeoFix™ with the NeoGuide™ Surgical Package for guided surgery and same-day PMMA provisional. The definitive NeoFix™ follows after healing.

How serviceable is a NeoFix™ prosthesis?

Highly. The doctor can remove it for cleaning, repair, or component replacement. The bar foundation is permanent; the prosthesis layer can be serviced or replaced over the lifetime of the implants.

contact us

Contact.

Contact.

Let’s Work Together

Connect with our lab today and experience craftsmanship, accuracy, and dependable service

Have a case to discuss?

Have a case to discuss?

Create a free website with Framer, the website builder loved by startups, designers and agencies.