NeoClip™ Removable Hybrid

Parallax Image
Parallax Image
Parallax Image

Hygiene First

Patients prioritizing hygiene and removability

Hygiene First

Patients prioritizing hygiene and removability

Hygiene First

Patients prioritizing hygiene and removability

Built Serviceable

Full-arch cases requiring long-term serviceability

Built Serviceable

Full-arch cases requiring long-term serviceability

Built Serviceable

Full-arch cases requiring long-term serviceability

Tunable Retention

Situations where retention tuning is preferred over fixed solutions

Tunable Retention

Situations where retention tuning is preferred over fixed solutions

Tunable Retention

Situations where retention tuning is preferred over fixed solutions

Bar Compatible

Bars already planned or fabricated

Bar Compatible

Bars already planned or fabricated

Bar Compatible

Bars already planned or fabricated

Removable clip-retained full-arch prosthesis over a verified CAD/CAM bar with metal mesh reinforcement patient removes for hygiene, retention is calibrated and adjustable.

Removable clip-retained full-arch prosthesis over a verified CAD/CAM bar with metal mesh reinforcement patient removes for hygiene, retention is calibrated and adjustable.

Removable clip-retained full-arch prosthesis over a verified CAD/CAM bar with metal mesh reinforcement patient removes for hygiene, retention is calibrated and adjustable.

Materials

Materials

Choice of Materials

Flexible material choices to ensure optimal performance and natural-looking outcomes.

CAD/CAM Titanium bar

CAD/CAM Titanium bar

CAD/CAM Titanium Metal Mesh Reinforcement

CAD/CAM Titanium Metal Mesh Reinforcement

Calibrated Clip Retention

Calibrated Clip Retention

Removable Prosthesis with Teeth Set-up

Removable Prosthesis with Teeth Set-up

WORKFLOW.

WORKFLOW.

Case Workflow

Step by Step

01

Verification & Records

Lab Provides:

CAD/CAM-milled 3D Verification Jig

Backup custom tray designed to fit over the verification jig

Bite block with two cylinders for VDO and bite registration

Doctor Performs:

Seat verification jig and confirm passive fit

Capture bite record using the bite block

Jig misfit requires suction and new pickup impression with custom tray.

Purpose:

Verify implant position, bar accuracy, and bite before prosthesis fabrication.

Verification & Records

Lab Provides:

CAD/CAM-milled 3D Verification Jig

Backup custom tray designed to fit over the verification jig

Bite block with two cylinders for VDO and bite registration

Doctor Performs:

Seat verification jig and confirm passive fit

Capture bite record using the bite block

Jig misfit requires suction and new pickup impression with custom tray.

Purpose:

Verify implant position, bar accuracy, and bite before prosthesis fabrication.

02

Clip Prosthesis Try-In & Approval

Lab Provides:

NeoClip™ CAD/CAM bar

NeoClip™ CAD/CAM metal mesh reinforcement

Teeth set-up with clip housing positions established

Doctor Confirms:

Esthetics (smile line, tooth display)

Phonetics, VDO, Path of insertion and removal

Bar seating and teeth try-in over the bar

Purpose:

Approve prosthesis design and retention strategy prior to final processing.

Clip Prosthesis Try-In & Approval

Lab Provides:

NeoClip™ CAD/CAM bar

NeoClip™ CAD/CAM metal mesh reinforcement

Teeth set-up with clip housing positions established

Doctor Confirms:

Esthetics (smile line, tooth display)

Phonetics, VDO, Path of insertion and removal

Bar seating and teeth try-in over the bar

Purpose:

Approve prosthesis design and retention strategy prior to final processing.

03

Final Fabrication & Delivery

Lab Delivers:

Final NeoClip™ removable prosthesis

Calibrated clip retention (per Rx)

Finished, polished, and QC-verified prosthesis

Doctor Performs:

Seat prosthesis and verify retention

Adjust retention strength if needed

Deliver hygiene and maintenance instructions

Purpose:

Approve prosthesis design and retention strategy prior to final processing.

Final Fabrication & Delivery

Lab Delivers:

Final NeoClip™ removable prosthesis

Calibrated clip retention (per Rx)

Finished, polished, and QC-verified prosthesis

Doctor Performs:

Seat prosthesis and verify retention

Adjust retention strength if needed

Deliver hygiene and maintenance instructions

Purpose:

Approve prosthesis design and retention strategy prior to final processing.

Case Workflow

Step by Step

01

Verification & Records

Lab Provides:

CAD/CAM-milled 3D Verification Jig

Backup custom tray designed to fit over the verification jig

Bite block with two cylinders for VDO and bite registration

Doctor Performs:

Seat verification jig and confirm passive fit

Capture bite record using the bite block

Jig misfit requires suction and new pickup impression with custom tray.

Purpose:

Verify implant position, bar accuracy, and bite before prosthesis fabrication.

Verification & Records

Lab Provides:

CAD/CAM-milled 3D Verification Jig

Backup custom tray designed to fit over the verification jig

Bite block with two cylinders for VDO and bite registration

Doctor Performs:

Seat verification jig and confirm passive fit

Capture bite record using the bite block

Jig misfit requires suction and new pickup impression with custom tray.

Purpose:

Verify implant position, bar accuracy, and bite before prosthesis fabrication.

02

Clip Prosthesis Try-In & Approval

Lab Provides:

NeoClip™ CAD/CAM bar

NeoClip™ CAD/CAM metal mesh reinforcement

Teeth set-up with clip housing positions established

Doctor Confirms:

Esthetics (smile line, tooth display)

Phonetics, VDO, Path of insertion and removal

Bar seating and teeth try-in over the bar

Purpose:

Approve prosthesis design and retention strategy prior to final processing.

Clip Prosthesis Try-In & Approval

Lab Provides:

NeoClip™ CAD/CAM bar

NeoClip™ CAD/CAM metal mesh reinforcement

Teeth set-up with clip housing positions established

Doctor Confirms:

Esthetics (smile line, tooth display)

Phonetics, VDO, Path of insertion and removal

Bar seating and teeth try-in over the bar

Purpose:

Approve prosthesis design and retention strategy prior to final processing.

Build Your Case

Start your case with precision workflows, flexible materials, and expert lab support at every step.

Framework (CAD/CAM Bar Material)

FAQ.

FAQ.

NeoClip™ Hybrid Support FAQs

Find answers about product specifications, workflows, and what to expect for each case.

How is clip retention calibrated and adjusted?

Clip retention is calibrated per Rx during final processing. Clips are replaceable and can be swapped chairside for stronger or weaker retention without remaking the prosthesis.

How often do clips need replacement?

Typically every 1–3 years depending on wear patterns and patient hygiene. Replacement is chairside and inexpensive — the bar and prosthesis are unaffected.

Can I switch a NeoClip™ patient to NeoFix™ later?

Sometimes — depends on the bar design and patient anatomy. Contact your account manager early; the bar may need modification to support a fixed prosthesis.

contact us

Contact.

Contact.

Let’s Work Together

Connect with our lab today and experience craftsmanship, accuracy, and dependable service

Have a case to discuss?

Have a case to discuss?

Create a free website with Framer, the website builder loved by startups, designers and agencies.